|
|
||||||||
USDA, ARS, Northwest Irrigation and Soils Research Laboratory, 3793 N 3600 E, Kimberly, ID 83341
* Corresponding author (lentz{at}nwisrl.ars.usda.gov)
| ABSTRACT |
|---|
|
|
|---|
Abbreviations: PVC, polyvinyl chloride SDF, sampler drainage fraction
| INTRODUCTION |
|---|
|
|
|---|
This problem may be lessened if tension samplers are designed with side walls. The soil volume confined in samplers with sidewalls is thought to reduce the influence of varying soil water potential on water flow through the sampler opening (Corey et al., 1982). If tension sampler sidewalls extend upward through the soil profile too far, however, they may interfere with subsurface lateral flow processes in some soils and bias measured downward fluxes and leachate solute concentrations. Annual percolation fluxes measured with walled fixed-tension samplers differed from tile-drain-flow values by 0 to 33% (Montgomery et al., 1987). Hergert (1986) reported that average annual percolation fluxes measured from fixed-tension samplers differed from water-balance values by 3 to 72%.
Duke et al. (1970) developed a mercury manometer and electrode-based controller for a soil water sampler system. When coupled with a soil tensiometer, the device automatically adjusted vacuum levels supplied to the sampler tension plate in relation to in situ soil water potential. In field tests, the manometer system proved to be impractical owing to its excessive maintenance requirements, and a manual system was substituted (Duke and Haise, 1973). More recently, Brye et al. (1999) deployed a rectangular equilibrium-tension sampler with 2.5-cm-high sidewalls. The researchers manually adjusted sampler suction to match the soil water potential of the surrounding bulk soil, which they measured with two heat-dissipation sensors. Brye et al. (1999) concluded that, while an automated sampler-suction control would have been an added refinement, the manual suction adjustment procedure was adequate for their field conditions because soil water potentials at the 1.4-m sampler depth tended to vary slowly. Natural rainfall supplied their field water inputs.
We installed vacuum extraction soil water percolation samplers in a medium-textured soil at the 1.2-m depth to intercept and sample both macro- and matrix-pore liquids in furrow-irrigated soils. Furrow irrigations supplied from 2 to 5 cm of water in a single 12- to 24-h irrigation and were repeated on 10- to 14-d intervals during the growing season. These inputs produced greater and more rapid changes in soil water content than may occur under natural rainfall. We wished to automatically adjust sampler extraction vacuum to in situ soil water tension conditions at each sampling site.
Initially, a mercury manometer switch was used to control extraction vacuum, with furrow inflow-end samplers maintained at a lower extraction vacuum than outflow-end samplers. However, operating the manometer was inconvenient because pressure switch settings were difficult to adjust and lacked precision, water contaminated the mercury and compromised electrode function, and the power supply transformer failed. Like Duke and Haise (1973), we decided that the mercury manometer-base system required excessive maintenance and was unreliable.
Our objective was to design and field test an automated vacuum controller that was capable of tracking ambient soil water tension near the soil water sampler opening, and adjusting sampler vacuum to a user-specified target value. This new system needed to be more reliable and require less maintenance than the mercury manometer systems.
| MATERIALS AND METHODS |
|---|
|
|
|---|
0.5 m apart and a tensiometer tube were installed at the 1.2-m depth at each of 12 sampling sites (Fig. 1)
located in a 48- by 122-m area within the plot. Half of the sampling sites were located 30 m from the furrow inflow end and half near the outflow end. A single vacuum source was located outside the plot, 70 m from the inflow-end of the field. A 15-mm polyethylene pipe connected the vacuum source to each site. A pressure transducer was sealed to the top of the tensiometer tube with connections linking it to the vacuum controller. An insulated cover placed over the projecting tensiometer tube and transducer moderated temperature effects on tension measurements. The controller was housed in an aboveground, insulated sample box and regulated the pressure in three collection flasks (one per sampler), also housed in the box. One Campbell Scientific Inc. 21X programmable data logger (Logan, UT)1 operated vacuum controllers and collected soil tensiometer, extraction pressure, soil temperature (thermocouples), and soil water content data (Campbell Scientific Inc. CS-615s) from three sampling sites. Table 1 lists the total number of components installed in the field plot for measuring and sampling soil water percolation.
|
|
A laboratory study determined how differences between sampler extraction tension and in situ soil tension influenced sampled percolate volume. We installed a percolation sampler of the above design in a 0.58-m-diam., 0.81-m-deep plastic barrel (Fig. 2) . Portneuf silt loam (coarse-silty, mixed, superactive, mesic Durinodic Xeric Haplocalcids) subsoil was sieved through a 5-mm screen and slurried into the barrel in four portions. Five 2.54-cm-diam., 67-cm-long glass fiber wicks allowed drainage to occur under tension. Irrigation water was applied to the soil surface at a constant rate of 0.25 mm h-1, a given extraction tension was applied to the percolation sampler for a period of 1 to 6 h, and sampler-drainage-rate and total-drainage-rate were measured using electronic scales. Sampler extraction tension was expressed as a fraction of the in situ soil tension and identified as the extraction-soil-tension ratio. The volume of percolate collected from the sampler per unit time was expressed as a fraction of the total drainage rate and termed the sampler drainage fraction (SDF). Assuming that downward water flux through the packed soil was uniform, the Expected SDF equaled (sampler cross-sectional area) x (total drainage cross-sectional area)-1. The experiment was run twice. We removed and inspected the sampler and reinstalled it in the barrel prior to the second run. Results of the second run were similar to those of the first.
|
|
7 cm above the soil surface. Prior to field operations, sensor leads and sampling tubes were coiled inside the lower riser, the upper riser section was removed, a cover placed over the lower riser, and the entire assembly buried. After tillage the lower riser was uncovered and the upper section replaced. We finished installing the sampling system in the fallowed plot in August and tested its operation under two irrigations applied in September.
Automated Vacuum Controller
Two pressure transducers and a simple electronic circuit were used to measure ambient soil and sampler extraction tension, and to open or close an electric valve connecting the sampler to the vacuum supply. The controller included a plastic enclosure, electric flow valve, and manifold mounted on a PVC sheet (Table 2). The enclosure contained a circuit board manufactured from our design by Idaho Instrument (Twin Falls, ID), and included terminal blocks for connections to the data logger, valve, and tensiometer transducer (Table 2). On the circuit board, a switching circuit (R1, Q1; Fig. 4
, Table 2) and relay controlled the flow valve circuit (D1, K1), 5 V regulated power supply circuit (U1) energized the transducers, and the sampler transducer circuit (H1) measured pressure supplying the three percolation sampler flasks.
|
|
1 A); +5 V (1.5 mA) digital output port control for the valve; and high and low differential analog inputs for the two transducers. Four lines connecting the controller to the remote soil tensiometer transducer provided excitation, ground, and signal voltage. Each controller cost approximately $123. This comprised $85 for parts and $38 labor, including a one-time set-up charge for circuit board fabrication.
Controller Operation
The data logger checked system pressures at the samplers, which required a correction for sampler-transducer elevation differences, and made necessary adjustments at each sampling site every minute. For each of the three sampling sites monitored by the data logger, the program looped through a 40-cycle comparison procedure, which required 16 s to complete. At the start of each comparison cycle the soil tension and sampler system pressure were compared. If the sampler pressure exceeded that required for optimal percolation water measurement, the program reduced system pressure by opening the flow valve connecting the sampler system to the vacuum source. If the flow valve was opened in a previous cycle, and either the system pressure had attained the target value, or the 40-count loop was completed, the program closed the vacuum flow valve. The program did not exit the 40-count loop once target pressure was attained, but continued to check and adjust pressures to ensure that system pressures were stable.
The control system was not designed to correct sampler system vacuum if it exceeded the soil-tension-based target value. Soil water flows to the samplers and a slight leakage of air through tubing or valve connections were large enough that they caused sampler system pressures to decline across time. This loss of vacuum was significant enough that sampler vacuum levels rarely lagged behind target values during a declining soil-tension event, as when soil water contents near samplers increased after irrigation.
If a soil tensiometer failed, causing the measured soil tension to fall below a user-defined value, the program would substitute either a mean soil tension value obtained from other vacuum controllers in the network, or a user-input soil tension value. This permitted the system to operate satisfactorily until the faulty tensiometer could be corrected.
| RESULTS AND DISCUSSION |
|---|
|
|
|---|
The laboratory tests indicated that an extraction-soil-tension ratio of 1.44 ± 0.10 was optimal for our sampler in these soils. Theoretical, 2-dimensional calculations by Corey et al. (1982) showed that a long, trough-shaped sampler with a rectangular opening and 0.2-m sidewalls would operate efficiently in soils similar to ours at a sampler-soil extraction-ratio of 1.2. The cylindrical percolation sampler used here differed from that in the Corey et al. analysis. Extraction vacuum was applied to the soil in our sampler through a ceramic membrane and a layer of fine silica flour. Pore size, and hence conductivity of these intervening materials was less than that for the soil. This likely increased applied extraction tensions required to match flow through intervening materials to that of soil, especially at higher water contents.
When the sampler extraction-tension ratio differs from the optimum, drainage flow lines converge or diverge at the sampler opening, and cause an increase or decrease in the sampler's effective collection area. The relative change in the collection area for a sampler with a circular opening, per unit increase in radius, is greater than that produced by a similar increase in the dimensions of a rectangular sampler. Thus, errors related to the estimation of percolation flux can be minimized by maintaining correct extraction tension on the circular samplers. Maintaining proper extraction tension is even more critical when sampling at more shallow soil depths where water content and flux are more dynamic, and when sampling in fine-textured, well structured soils (Corey et al., 1982).
We installed automated vacuum controllers and soil tensiometers at each sampling site to reduce field labor requirements and increase sampling efficiency. This equipment adjusted sampler extraction pressure for individual sites, in response to soil tensiometer measurements taken at each site. This system was able to address both spatial and temporal variation.
The controller successfully regulated extraction vacuum in accordance with site soil water potential. Figure 5 illustrates the change in 1.2-m soil water potential and sampler extraction pressure that occurred across 13 d, starting on the day of a furrow irrigation (209, 28 July). The sampler extraction pressure paralleled the 1.2-m soil water potential closely. The sampler-soil extraction ratio ranged from 1.4 to 2.0 with a 13-d mean of 1.56. The sampler extraction pressure shown in Fig. 5 was measured after each adjustment cycle had been completed. The sampler system pressure increased slowly until the next adjustment event reestablished target pressure levels. Thus, just prior to the adjustment events, the sampler-soil extraction ratio values had decreased to values that ranged from 1.3 to 2 and averaged 1.41 during the 13-d period. The automated controllers functioned well for two irrigation seasons, although occasional problems did occur. When collecting water samples from flasks, tubing can become inadvertently kinked. This can reduce air flow and prevent equilibration between vacuum supply and sampler system when the valve is opened. Sampler system flow exceeded the valve flow capacity at two sample sites. To maintain system pressure at sufficiently low levels, we had to connect the samplers at these sites directly to the vacuum supply. Some controller/electronic valve systems were subject to heavier duty cycles than others. The valves on these controllers worked well for two months of intense usage. Eventually, however, the flow rate through these components decreased until the controllers were unable to supply enough vacuum to the three collection flasks. These valves had to be replaced, although it is possible that they could have been refurbished. Temperature-induced fluctuations in soil tension measurements were apparent in tensiometer responses. These could be avoided by using an advanced tensiometer design (Hubbell and Sisson, 1998).
|
The percolation samplers performed satisfactorily in the 3 yr following installation (results to be published in a later paper). No trend of reduced percolation with time was apparent in water volumes collected across three irrigation seasons, suggesting that clogging of ceramic-cup pores with precipitating CaCO2 was a minor concern for these calcareous soils. Two buried data logger conductors failed during the period and were replaced by surface-run cables. Rodents like to chew on the Teflon sampler tubes. Traps and chemical deterrents helped to exclude them from the risers and buried cable runs. Each year we committed
40 man-hours of labor to install and remove equipment from the plot. An additional 15 man-hours were used to connect the extensive network of thermocouple and CS-615 sensors. Two to four individuals would move equipment out of the tractors path during the single cultivation done on the plot each year (2 to 4 man-hours).
Overall, the automated vacuum controllers were more effective than the mercury manometer used early in the study. The automated system was able to respond to spatially variable soil water potential conditions in the study area. The controllers were more reliable, and the level of maintenance required by the 12 field units was no greater than that required for the mercury manometer system. The automated system maintained a minimum sampler extraction pressure of
-70 kPa. Lower values would have produced extraction pressures at the sampler that exceeded the air entry pressure for the intake membrane. The controllers could function at even lower extraction pressures, for example, in systems having membranes with -100 kPa air-entry pressures, assuming that the system air-extraction rates were similar to ours.
The use of data loggers to operate the controllers was not a detraction because they were required for logging soil water content and temperature. Besides operating the vacuum controllers, the data loggers also recorded ambient soil water potential and sampler system pressure at each site. This information improved our ability to correctly interpret the field data. This system also allows the option of changing the sampler-soil tension ratio depending on soil tension or other factors.
| ACKNOWLEDGMENTS |
|---|
| NOTES |
|---|
|
|
|---|
Received for publication December 5, 2001.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
J. Mertens, J. Diels, J. Feyen, and J. Vanderborght Numerical Analysis of Passive Capillary Wick Samplers prior to Field Installation Soil Sci. Soc. Am. J., January 1, 2007; 71(1): 35 - 42. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Morari Drainage Flux Measurement and Errors Associated with Automatic Tension-controlled Suction Plates Soil Sci. Soc. Am. J., September 20, 2006; 70(6): 1860 - 1871. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. D. Lentz Solute Response to Changing Nutrient Loads in Soil and Walled Ceramic Cup Samplers under Continuous Extraction. J. Environ. Qual., September 1, 2006; 35(5): 1863 - 1872. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Mertens, G. F. Barkle, and R. Stenger Numerical Analysis to Investigate the Effects of the Design and Installation of Equilibrium Tension Plate Lysimeters on Leachate Volume Vadose Zone J., June 9, 2005; 4(3): 488 - 499. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.M. Norman, K.C. Masarik, K.R. Brye, and J.M. Baker Reply J. Environ. Qual., March 1, 2005; 34(2): 409 - 410. [Full Text] [PDF] |
||||
![]() |
K. C. Masarik, J. M. Norman, K. R. Brye, and J. M. Baker Improvements to Measuring Water Flux in the Vadose Zone J. Environ. Qual., May 1, 2004; 33(3): 1152 - 1158. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Kosugi and M. Katsuyama Controlled-Suction Period Lysimeter for Measuring Vertical Water Flux and Convective Chemical Fluxes Soil Sci. Soc. Am. J., March 1, 2004; 68(2): 371 - 382. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Baker Recalcitrant Problems in Environmental Instrumentation Agron. J., November 1, 2003; 95(6): 1404 - 1407. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| The SCI Journals | Agronomy Journal | Crop Science | |||
| Vadose Zone Journal | Journal of Plant Registrations | ||||
| Journal of Natural Resources and Life Sciences Education |
Journal of Environmental Quality |
||||