Fig. 1 Measured and predicted water retention curves for samples a14 and a82 (Profile A) and a60 and a52 (Profile B). Predicted curves are as follows: unimodal van Genuchten
(h),
s optimized (VGopt) or fixed at the measured value (VGfix); bimodal van Genuchten
(h) as proposed by Durner (VGbim); bimodal
(h) as proposed by Ross and Smettem (RSbim)
|