SSSAJ Journal of Natural Resources and Life Sciences Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online 29 June 2007
Published in Soil Sci Soc Am J 71:1288-1291 (2007)
DOI: 10.2136/sssaj2007.0007
© 2007 Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ajiboye, B.
Right arrow Articles by Jürgensen, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Ajiboye, B.
Right arrow Articles by Jürgensen, A.
Agricola
Right arrow Articles by Ajiboye, B.
Right arrow Articles by Jürgensen, A.
Related Collections
Right arrow Soil Analysis
Right arrow Soil Chemistry

SOIL CHEMISTRY

Experimental Validation of Quantitative XANES Analysis for Phosphorus Speciation

Babasola Ajiboyea, Olalekan O. Akinremia,* and Astrid Jürgensenb

a Dep. of Soil Science, Univ. of Manitoba, 13 Freedman Crescent, Winnipeg, MB Canada R3T 2N2
b Canadian Synchrotron Radiation Facility, Synchrotron Radiation Center, Univ. of Wisconsin-Madison, Stoughton, WI 53589-3097

* Corresponding author (Akinremi{at}ms.umanitoba.ca).

The quantitative approach used in x-ray absorption spectroscopy (XAS) experiments is oftentimes based on statistical goodness-of-fit criteria, which do not explain the accuracy of the components obtained from the fittings. This study was performed to validate the linear combination (LC) approach used in quantitative XAS analysis by estimating the accuracy of this procedure. Near-edge K{alpha}1 fluorescence XAS spectra were acquired for known binary mixtures of Ca, Al, and Fe phosphates in varying proportions and for the individual compounds. All combinations of the spectra of model compounds were fitted to the spectra of the known mixtures to obtain their relative abundance. The binary combinations produced the best fit with {chi}2 values ranging from 0.02 to 0.25. The relative error associated with the fitting ranged from as low as 0.8 to 17% for thoroughly mixed samples. The relative error was small when the proportion of Ca phosphate in the mixture was high but the error was large at low abundance of this component in the mixture. Because the interpretation of the XANES result largely depends on the relative proportion of species in the sample obtained by LC, we therefore recommend acquiring a spectrum for a mixture of certified reference compounds that mimics the composition of the sample being investigated at the beamline to estimate the accuracy of the proportions obtained from quantitative x-ray absorption near-edge structure (XANES) analysis.

Abbreviations: HAP, hydroxyapatite • LC, linear combination • PSIDER, phosphosiderite • VAR, variscite • XANES, x-ray absorption near-edge structure • XAS, x-ray absorption spectroscopy







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Journal of Natural Resources
and Life Sciences Education
Vadose Zone Journal
Journal of Plant Registrations Journal of
Environmental Quality
The Plant Genome
Copyright © 2007 by the Soil Science Society of America.