SSSAJ Journal of Natural Resources and Life Sciences Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online 29 March 2006
Published in Soil Sci Soc Am J 70:711-717 (2006)
DOI: 10.2136/sssaj2005.0174
© 2006 Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Figures Only
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gao, J.
Right arrow Articles by Gong, Y.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Gao, J.
Right arrow Articles by Gong, Y.
Agricola
Right arrow Articles by Gao, J.
Right arrow Articles by Gong, Y.
Related Collections
Right arrow Flow
Right arrow Soil Physics

Soil Physics

Correcting Wall Flow Effect Improves the Heat-Pulse Technique for Determining Water Flux in Saturated Soils

Jianying Gao, Tusheng Ren and Yuanshi Gong*

College of Resource and Environmental Sciences, China Agricultural Univ., Beijing, China 100094

* Corresponding author (gongys{at}cau.edu.cn)

Heat-pulse sensors are promising tools that can provide rapid measurements of soil water fluxes. The main objective of this study was to determine whether wall flow could be a main reason for discrepancies between measured and heat-pulse water flux densities. Heat-pulse measurements were obtained with a range of water flux densities imposed on packed soil columns of three saturated media: glass beads, a sandy loam soil, and a sandy clay loam soil. Water flux density was calculated from the thermal properties of the media and the ratio of temperature changes at downstream and upstream positions. A novel finding from this study was that in packed columns, wall flow was responsible for the deviations between water flux estimates from heat-pulse data and water flux measured from outflow, and the magnitude of wall flow was largely determined by soil texture. An amplification factor, 1.12 for the sandy loam and 1.24 for the sandy clay loam, was introduced to correct the influence of wall flow, which reduced the errors of the heat-pulse measurements to within 5%. We demonstrated that wall flow was able to explain quantitatively the "reduced convection" theory proposed by earlier researchers. Under the experimental conditions, heat transfer by dispersion was of minor importance.




This article has been cited by other articles:


Home page
Vadose Zone JHome page
M. H. Young, G. S. Campbell, and J. Yin
Correcting Dual-Probe Heat-Pulse Readings for Changes in Ambient Temperature
Vadose Zone J., January 23, 2008; 7(1): 22 - 30.
[Abstract] [Full Text] [PDF]


Home page
Soil Sci.Home page
G. J. Kluitenberg, T. E. Ochsner, and R. Horton
Improved Analysis of Heat Pulse Signals for Soil Water Flux Determination
Soil Sci. Soc. Am. J., January 1, 2007; 71(1): 53 - 55.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Journal of Natural Resources
and Life Sciences Education
Vadose Zone Journal
Journal of Plant Registrations Journal of
Environmental Quality
The Plant Genome
Copyright © 2006 by the Soil Science Society of America.