SSSAJ Journal of Natural Resources and Life Sciences Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Robinson, D. A.
Right arrow Articles by Shouse, P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Robinson, D. A.
Right arrow Articles by Shouse, P.
Agricola
Right arrow Articles by Robinson, D. A.
Right arrow Articles by Shouse, P.
Related Collections
Right arrow Soil Methods/Instrumentation
Right arrow Soil Salinity
Right arrow Electromagnetic Induction, EMI
Published in Soil Sci. Soc. Am. J. 68:339-345 (2004).
© 2004 Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA

DIVISION S-1—SOIL PHYSICS

Minimizing Drift in Electrical Conductivity Measurements in High Temperature Environments using the EM-38

D. A. Robinson*, I. Lebron, S. M. Lesch and P. Shouse

USDA-ARS, George E. Brown, Jr. Salinity Lab., 450 W. Big Springs Road, Riverside, CA 92507

* Corresponding author (darearthscience{at}yahoo.com).

The EM-38 is a noninvasive instrument, commonly used for monitoring salinity, mapping bulk soil properties, and evaluating soil nutrient status. Users in the Southwest USA have observed as much as 20% "drift" in the measurement of bulk soil electrical conductivity (ECa) with this instrument. This drift has usually been ignored or compensated for by statistical procedures. We performed laboratory and field experiments to determine if the drift is due to calibration instability of the instrument or to heating of the instrument by the sun. In laboratory experiments, after a warm-up period, the instrument provided constant readings in the range 25 to 40°C; above 40°C the response of the instrument was unpredictable. In field experiments, where we placed the EM-38 in a fixed location we observed an unexpected response at air temperatures below 40°C. Temperature sensors in different locations on the instrument demonstrated that temperature differences between the instrument's transmitting and receiving coils and the control panel (CP) were as great as 20°C. As the instrument is temperature compensated from this CP, erroneous compensation occurred when the instrument was placed in direct sunlight. In this study, we demonstrate that differential heating of the EM-38 is one cause of drift and erroneous bulk electrical conductivity measurement; shading the instrument substantially reduced this problem, effectively extending the reliable working temperature range by minimizing drift.

Abbreviations: CP, control panel • ECa, bulk soil electrical conductivity • Hi, induced magnetic field • Hp, primary magnetic field • Rx, receiving coil • Tx, transmitting coil




This article has been cited by other articles:


Home page
Soil Sci.Home page
H. Abdu, D.A. Robinson, and S.B. Jones
Comparing Bulk Soil Electrical Conductivity Determination Using the DUALEM-1S and EM38-DD Electromagnetic Induction Instruments
Soil Sci. Soc. Am. J., January 1, 2007; 71(1): 189 - 196.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Journal of Natural Resources
and Life Sciences Education
Vadose Zone Journal
Journal of Plant Registrations Journal of
Environmental Quality
The Plant Genome
Copyright © 2004 by the Soil Science Society of America.