SSSAJ Journal of Natural Resources and Life Sciences Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Biesheuvel, P.M.
Right arrow Articles by Verweij, H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Biesheuvel, P.M.
Right arrow Articles by Verweij, H.
GeoRef
Right arrow GeoRef Citation
Agricola
Right arrow Articles by Biesheuvel, P.M.
Right arrow Articles by Verweij, H.
Soil Science Society of America Journal 63:1571-1579 (1999)
© 1999 Soil Science Society of America

DIVISION S-1-SOIL PHYSICS

Response of the Osmotic Tensiometer to Varying Temperatures

Modeling and Experimental Validation

P.Maarten Biesheuvela, Ron Raangsb and Henk Verweija

a Lab. for Inorganic Materials Sci., Dep. of Chem. Technol. and MESA Res. Inst., Univ. of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
b Dep. of Environ. Sci., Subdep. Water Resour., Wageningen Univ., Nieuwe Kanaal 11, 6709 PA Wageningen, The Netherlands

h.verweij{at}ct.utwente.nl

In an osmotic tensiometer, the hydrostatic pressure of a confined polymer solution is measured to infer the soil water potential. Essential in the operation is the osmotic potential of the polymer solution. Because the osmotic potential depends on the temperature, a significant and undesired pressure lag may develop when the osmotic tensiometer is used under conditions of varying temperature. To understand and eliminate the pressure lag, a dynamic transport model was derived that describes the time response of the osmotic tensiometer while assuming complete temperature equilibration and a resistance to water transfer that is fully located within the filter. Essential elements of the model are the filter conductance and the sensitivity of the pressure transducer, for which submodels are set up. The transport model is validated with measurements on an osmotic tensiometer that uses an inorganic membrane as filter. The experiments were done for instrument-limited conditions by placing the osmotic tensiometer in free water. For these conditions, the model describes measurements with reasonable accuracy. The new transport model clarifies the behavior of the osmotic tensiometer for changing temperatures and can be used to design an osmotic tensiometer with a lower pressure lag.




This article has been cited by other articles:


Home page
Vadose Zone JHome page
G. Bakker, M. J. van der Ploeg, G. H. de Rooij, C. W. Hoogendam, H. P. A. Gooren, C. Huiskes, L. K. Koopal, and H. Kruidhof
New Polymer Tensiometers: Measuring Matric Pressures Down to the Wilting Point
Vadose Zone J., February 27, 2007; 6(1): 196 - 202.
[Abstract] [Full Text] [PDF]